Atomizers

Aseptanios airborne disinfection

Discover
Peracetic acid and hydrogen peroxide based solution for airborne disinfection of surfaces and non-invasive medical devices previously cleaned.

MYFOG Fog generator for airflow visual testing, AM Instruments

Discover
Applications:
• visualisation of airflow directions in ISO classified environments and laminar flow areas (ie: liquids filling machines)
• Visualization of inter-zone flows
• Identification of air stagnation pockets
• Personnel training

The MyFog generator from AM Instruments, allows instant verification of airflow behaviour in Environments that do not tolerate cross contamination. In accordance with ISO 14644-3 Annex B7, airflows in Controlled Environments and ISO classified environments must be checked periodically. The tests are carried out in areas without human activity, the visualisation of air flows is carried out by generating a non-polluting fog.

HALO C Smart et HALO P Smart Laboratory air filtration system

Discover
• Pulls dirty air in the lab through the filter / returns clean, filtered air back to the room
• Two types of purifiers, Halo C or Halo P (gas filtration or particle filtration)
• No connection needed to the general ventilation of the building
• Very low energy consumption (50w)
• No direct pollutant releases to the outside
• Does not require the addition of new sensors
• Light pulsation communication
• eGuard App to monitor remotely via smartphone, tablet or PC
• Compatible with GTB systems

Four operating modes:
• Day / night mode:
This mode allows you to apply ventilation instructions for a "Day" time frame (between 8:00 and 20:00) and "NIGHT" time frame (20:00-8:00)
• Unique detection mode:
The ventilation system is inactive. It activates at maximum power if the air quality sensor reaches the detection threshold defined in the parameters
• 24 / 24 h Mode:
Halo's ventilation system runs 24 hours a day - 7 days a week
• Min Max detection mode:
This mode defines a minimum and maximum ventilation power. In normal operation, the ventilation power is set by the parameter registered in Min. The Halo reaches its maximum ventilation power if the air quality sensor detects a pollution in the ambient air (the threshold of the sensor defined in the parameters is reached)